LEDPRO · Heavy Duty · GEN1 & GEN2

Heavy Duty Flood Lights

Powerful area and working light for industrial sites, ports, cranes and sports facilities. A comprehensive range of optics helps direct the light where your project needs it.

Krachtige terrein- en werkverlichting voor industrie, havens, kranen en sportlocaties. LEDPRO helpt bij de keuze van vermogen, lichtverdeling, montage en aansturing.

GEN1 · 60–1500 WGEN2 · 60–1200 WIP653000–6500 K0–10 V / DALI options
60–1500 WCombined nominal range
IP65Outdoor protection
135–143 lm/WDepending on optics
4 CCT options3000 / 4000 / 5000 / 6500 K

Key advantages

Light where it matters

A choice of narrow, wide and asymmetric distributions for area lighting and focused working light.

Gerichte verlichting — Stem de lichtverdeling af op werkvlak, montagehoogte en omgeving.

Engineered for demanding sites

Fold-fin aluminium cooling, tempered glass and an IP65 enclosure for professional outdoor applications.

Robuuste constructie — Aluminium koeling en gehard glas voor industriële toepassingen.

Project-specific configuration

Choose the generation, output, colour temperature, optics and optional dimming to suit the installation.

Technische begeleiding — Advies over lichtberekening, bevestiging en aansturing.

Product impressions

Heavy Duty floodlight · compact housing
Heavy Duty floodlight · compact housing
Heavy Duty floodlight · front and bracket
Heavy Duty floodlight · front and bracket
Heavy Duty floodlight · larger housing
Heavy Duty floodlight · larger housing

GEN2 · 60–1200 W

Single-PCB models from 60 to 400 W and dual-PCB models from 500 to 1200 W. The model rating and typical system consumption are shown separately.

De modelaanduiding is niet altijd gelijk aan het opgenomen systeemvermogen. Gebruik de kolom System W voor de elektrische belasting.

ModelNominal WSystem WTypical lmWeight kgA × B × C (mm)
FL2-060-G260669,4004.2259 × 367 × 91
FL2-080-G2808512,1005.9310 × 367 × 91
FL2-100-G210010014,1005.9310 × 367 × 91
FL2-120-G212013018,5007.2360 × 367 × 91
FL2-150-G215015522,1007.2360 × 367 × 91
FL2-200-G220022031,3008.2411 × 367 × 91
FL2-250-G225025035,6008.9461 × 367 × 91
FL2-300-G230031044,10011.1562 × 367 × 91
FL2-350-G235037052,60012.3663 × 367 × 91
FL2-400-G240044062,60012.3663 × 367 × 91
FL2-500-G250050071,20021.5584 × 672 × 116
FL2-600-G260062088,20022.2584 × 672 × 116
FL2-800-G2800880125,30021.5 *788 × 583 × 116
FL2-1000-G210001000142,40021.5 *788 × 583 × 116
FL2-1200-G212001200170,80025.3 *938 × 583 × 116

* GEN2 models from 800 W use remote drivers. These weights are for the fixture only; weights up to 600 W include the built-in drivers. Luminous flux is typical and depends on optics.

Dimensions & mounting

GEN2 · dimensional drawings and dimensions in millimetres
GEN2 · dimensional drawings and dimensions in millimetres

Click the drawing to enlarge. Confirm detailed fixing dimensions and remote-driver arrangements for the selected model.

GEN1 · 60–1500 W

The established AFL / AFLS PLUS range, with separate light-output values for 60° × 60° and 85° × 90° optics.

ModelNominal WSystem Wlm · 60° × 60°lm · 85° × 90°Weight kgDimensions mm
AFL-06060668,9189,2636.5327 × 367 × 91
AFL-080808812,07412,5407327 × 367 × 91
AFL-10010011015,09215,6757.5387 × 367 × 91
AFL-12012013218,11018,8108387 × 367 × 91
AFL-15015016522,63823,5138387 × 367 × 91
AFL-20020022030,18431,3509507 × 367 × 91
AFL-25025026035,67237,0509507 × 367 × 91
AFL-30030032043,90443,32010.5567 × 367 × 91
AFL-35035037551,45053,43817.5533 × 621 × 117
AFL-40040044060,36862,70018533 × 621 × 117
AFL-50050052071,34474,10021593 × 621 × 117
AFL-60060062085,06483,93321.5593 × 621 × 117
AFLS-800800880120,736125,40029833 × 621 × 117
AFLS-100010001100150,920156,75038743 × 764 × 170
AFLS-125012501350185,220192,37527.4 *788 × 665 × 161
AFLS-150015001500205,800213,75027.4 *788 × 665 × 161

* AFLS-1250 / AFLS-1500 fixture weights exclude the separate 10.5 kg driver box. Values are typical. Confirm the selected configuration for each project.

Dimensions & mounting

GEN1 · dimensional drawings and mounting options
GEN1 · dimensional drawings and mounting options

Technical specifications

SpecificationGEN2 · HDFL-G2GEN1 · AFL / AFLS PLUS
Nominal range60–1200 W60–1500 W
LED sourceLumileds / Osram 5050Lumileds 5050
Colour temperatures3000 / 4000 / 5000 / 6500 K3000 / 4000 / 5000 / 6500 K
Colour renderingCRI >70; >80 optionalCRI >70; >80 optional
System efficacy135–143 lm/W, optics dependent135–143 lm/W, optics dependent
Ingress protectionIP65IP65
DriverMean WellMean Well / Inventronics
Input voltage90–305 VAC; 347–480 VAC optional100–305 VAC / 347–480 VAC, 50/60 Hz
Power factor / electrical class>0.90 / Class I>0.90 / Class I
Dimming options0–10 V / DALI0–10 V / DALI
Operating temperature−40 to +45 °C−40 to +45 °C
Storage temperature−25 to +80 °C−25 to +80 °C
Housing / optical coverAluminium heatsink / tempered glassAluminium / tempered glass
FinishBlack powder coat; custom RAL on requestBlack powder coat; custom RAL on request

Optics & control

GEN2 distributions

Round: 20° × 20°, 30° × 30°, 60° × 60°

Square: 60° × 60°, 90° × 90°

Asymmetric: 45° × 145°, 70° × 145°, 60° × 90°, 60° × 135°

Ultra-asymmetric: 30° × 95°, 60° × 140°

GEN1 distributions

Symmetric: 30° × 30°, 45° × 45°, 60° × 60°, 75° × 75°

Asymmetric: 85° × 45°, 85° × 90°, 85° × 135°, 60° × 135°

Non-dimmable, 0–10 V and DALI configurations are available depending on the selected driver.

Optics listed follow the existing LEDPRO product sheets. Ask LEDPRO for photometric files and a configuration suitable for your project.

Mounting & accessories

ItemApplication
GEN2 trunnion bracket / slip fitterMounting options to suit the installation; confirm model compatibility.
GEN2 NEMA receptacleOptional 5-pin or 7-pin configuration.
GEN1 sensor mountingCustom bracket design for separately ordered sensors.
Marine / salt-water applicationsSpecify the bracket material and corrosion protection for the actual environment.
Remote driver placementConfirm cable lengths, fixing details and enclosure requirements with LEDPRO.

Project photos

Existing LEDPRO application photographs: floodlighting on cranes, ships and working areas.

Working-area lighting at night
Working-area lighting at night
Crane floodlighting
Crane floodlighting
Heavy Duty application overview
Heavy Duty application overview
LEDPRO project photo · 01
LEDPRO project photo · 01
LEDPRO project photo · 02
LEDPRO project photo · 02
LEDPRO project photo · 03
LEDPRO project photo · 03
LEDPRO project photo · 04
LEDPRO project photo · 04
LEDPRO project photo · 05
LEDPRO project photo · 05
LEDPRO project photo · 06
LEDPRO project photo · 06

Click a photograph to view the original at full size.

Product documentation

Technical data, dimensions and ordering information for both generations.

Discuss your project with LEDPRO

Tell us about the application, mounting height and area to be illuminated. We can help select the output, optics, mounting and control options.

Stuur een tekening of foto's van de situatie. We denken mee over een passende uitvoering en lichtverdeling.

Request information ↗
Don`t copy please